hanged after
setting the ON pressure.
Hysteresis setting trimmer
Pressure setting trimmer
Indicator light HYS
SE1(L)- 16/-17
? With pressure setting trimmer 1 (SET 1), OUT
1 (Black lead wire, Red LED) can be set.
? With pressure setting trimmer 2 (SET 2), OUT
2 (White lead wire, Green LED) can be set.
IZ
Pressure setting trimmer 2
Pressure setting trimmer 1
SET1
Indicator light SET2
Set point
Supply pressure
Atmospheric
pressure 0
Unsteady
adsorption
Non adsorption
Steady adsorption
High vacuum
? Regarding the pressure setting
? Set the possible min. pressure for adsorption
confirmation. If setting the pressure lower
than that, switch becomes ON in case that
adsorption is not completely done. If setting
the pressure higher than that, switch does
not become ON even though it may absorb
workpieces.
Observe the following precautions for setting
the vacuum pressure:
Use your fingertips to gently turn the
screwdriver.
Do not use a screwdriver with a large grip or
with a tip that does not fit into the trimmer
groove because this could strip the groove.
Hysteresis
Hysteresis is the pressure difference between the ON and
the OFF pressure of the output signal. The set pressure is
the pressure selected to switch from OFF to ON condition.